Members Login
Username 
 
Password 
    Remember Me  
Post Info TOPIC: exhaust system design for beta 50 hp


Member

Status: Offline
Posts: 5
Date:
exhaust system design for beta 50 hp


Hi Stanley,

would greatly appreciate you advice.

first my old system see attached (pic 02,52,33)-had 60 hp perkins #4203 repowering with Beta 50hp.

next plan A system (see attached drawing) with two waterlocks drawing.

even with the two waterlocks I don't think they can handle the volume of water in the 9'6 hose. (This is my only waterlock option with my limited space available) my old system makes since to me as there is no way watercan travel from the port side to the STB side muffler. but is a 90 degree bend and aprox 3' rise to much back pressure?2017-04-15 07.39.33.jpg2017-04-06 10.27.39 HDR.jpg2017-04-06 10.34.02.jpgshimoda plan A.jpg

 

 



Attachments
__________________


Guru

Status: Offline
Posts: 958
Date:

Hello and welcome to the forum,

I think that your standpipe arrangement as used on the old engine should work just fine.
I would definetely build a new one and also include a new flex section between the engine and the standpipe.
It won't hurt to fit an anti siphon valve in the water line between the heat exchanger and the water injection point of the standpipe as well. This will also be mounted above the waterline.

I hope that this helps, Stanley



__________________


Member

Status: Offline
Posts: 5
Date:

Hi Stanley,

Thank you so much for your advice.

I have drawn in an anti siphon loop as you suggested.

but I have a mystery, its been 10 yrs since I pulled the motor and I don't remember what the 1/2"  fitting on the upper fitting of the water jacket went to, any thoughts anti siphon.png



Attachments
__________________


Guru

Status: Offline
Posts: 958
Date:

Is it possible that the 1/2" fitting went to the stuffing pox for cooling?
This fitting is not really needed for the exhaust system to function.
The anti-siphon valve as you have drawn it wont work.

__________________


Member

Status: Offline
Posts: 5
Date:

anti siphon.pngHi Stanley,

I am confused "fit an anti siphon valve in the water line between the heat exchanger and the water injection point"

could you draw in where it should be.

the stuffing box is not water cooled, could it be a secondary supply form the heat exchanger line  or from the heat exchanger for the velvet transmission ?



__________________


Guru

Status: Offline
Posts: 958
Date:

I have attached a basic drawing showing how an anti-siphon valve (vented loop) should be connected.

I don't know what that extra fitting is for.



-- Edited by Stanley on Thursday 20th of April 2017 09:58:19 AM

Attachments
__________________


Member

Status: Offline
Posts: 5
Date:

Hi Stanley,it looks like what I have drawn in the above post will work-yes?

beta.jpg



Attachments
__________________


Guru

Status: Offline
Posts: 958
Date:

NO. What you have drawn will not work!

 

If you actually study the drawing that I posted and the one from our website you will see that the water exits the heat exchanger, runs up to the anti siphon valve and then down to the water injection point on the exhaust water injection elbow. 



__________________


Member

Status: Offline
Posts: 5
Date:

Stanley, it is very obvious now. I didn't understand that  for the anti siphon to work it needs to be part of and wholly contained in the water supply line.

thank you again for helping me with my exhaust system and mostly bearing with me .oh and I am thinking that the 1/2" fitting went the hot water tank.anti siphon.png



Attachments
__________________
Page 1 of 1  sorted by
 
Quick Reply

Please log in to post quick replies.

Tweet this page Post to Digg Post to Del.icio.us


Create your own FREE Forum
Report Abuse